Tuning FreeBSD for different applications:A guide to server and workstation optimization, by Avleen Vig |
Server and workstation tuning is an ongoing process.
Believing that you are done only means that you don't know what else can be tuned.
This article should apply equally to FreeBSD 4.x and 5.x
The method of tuning your system is heavily dependent on its function:
How you answer these and other questions determines what you need to do
to improve the performance of your system.
There are several steps you
can take before you need to start changing sysctls or re-arranging your
partitions. How your applications are compiled plays a major role too.
Beyond application compilation we will look at tuning the various other
parts of our system including the network, disks, and other system control
functions. I have tried not to duplicate the data in the tuning(7) man
page, which already contains a wealth of good information on the basics of
system performance tuning.
When source code is compiled, your compiler makes assumptions about your hardware in order to create compatible binaries. If you have an x86-complient CPU for example, your compiler will by default create binaries which can be run on any CPU from a 386 onwards. While this allows portability, any new abilities your CPU advantage of (MMX, SSE, SSE2, 3DNow!, etc) will not be used. So portability creates inefficiency. This is also why using pre-compiled binaies on your system is a sure fire way to reduce your overall performance!
System tuning is best performed on a new system, before many packages
are installed. The steps you take here will also effect any new software
you install. We assume that your packages are installed from the ports
collection (/usr/ports). These steps should be applicable to
any other software compiles and we will cover that later in this
paper.
The first step to making sure your ports software will be compiled
effeciently is to have good compiler flags set up. These are defined in
/etc/make.conf. This file does not exist on new systems, but
you can copy /etc/defaults/make.conf to
/etc/make.conf.
Edit the file, and look for the line
starting: #CPUTYPE=
Valid options for the CPUTYPE are
listed in the file, in the paragraph above this line. My server is a
P233/MMX, and my CPUTYPE line looks like:
CPUTYPE=i586/mmx
What this does: The CPUTYPE
option notifies the compiler of any special features your CPU has. The
compiler will then, where possible, compile code to take advantage of
these features. The disadvantage to this is that your compiled binaries
may not run on different CPU types. As long as you aren't copying binaries
from one server to another, this should not be a problem.
Also in the file, look for the line: #CFLAGS= -O -pipe
Uncomment this line, and change it to: CFLAGS= -O2 -pipe
-funroll-loops
What this does: The '-O2' flag sets the optimization level. GCC has
the following possible optimization levels:
The '-pipe' option decreases the amount of time taken to compile
software. When two compiler processes need to communicate data between
each other, they can use files on the disk or pipes. As pipes do not
require writing anything to disk they can significantly decrease the
amount of time taken here.
Finally, '-funroll-loops' causes finite loops to be "unrolled". When a
binary compiled with this option is run, the CPU does not have to run
through every possible itteration of the loop to get its result. Instead,
loops are replaces with with their equivilent non-looping code. This
saves one CPU register which would otherwise be tied up in tracking the
itteration of the loop.
The gcc man page (man gcc) is a good resource for this.
Warning: It has been noted that for some users on FreeBSD 4.8 and 4.9, the -funroll-loops causes SSHv2 with the base OpenSSH to break. Installing the OpenSSH-portable port to overwrite the base install fixes this problem quickly and easily, and provides a newer version of OpenSSH:
cd /usr/ports/security/openssh-portable && \
make install -DOPENSSH_OVERWRITE_BASEThe make.conf file also contains a line for CXXFLAGS.
These options are similar to our CFLAGS options but are used for C++ code.
If you are going to compile C++ code, you should take a look at this
also.
Efficient kernel compiling is covered in my Kernel Tuning paper at: http://silverwraith.com/papers/freebsd-kernel.php
How you optimize your system for networking depends on what your system will be doing. Below we will take a look at two common applications for servers, Mail and File serving.
There are a number of steps which can be applied to all installations to improve network performance, and should be done by everyone.
Most modern network cards and switches, support the ability to
auto-negotiate the speed to communicate at. While this reduces
administration is, it comes at the cost of network throughput. If your
switch, server or workstation is set to use auto-negotiation, every few
moments it stops transferring network traffic in order to renegotiate its
speed. On low-bandwidth use networks this performance degradation might be
hard to spot, but on high-bandwidth use networks it become very obvious:
You have packet loss, you cannot achieve your full line speed, and your
CPU usage is low. I would recommend that everyone read the man page on
their network driver and manually define the network speed. This should if
possible, also be done on the network switch. Some simple $10 switches do
not have interfaces to which you can log in to set this, but fortunately
they usually do not renegotiate the network speed after the cable is
plugged in, unless the network link is lost.
The network speed can
either be set with ifconfig at run time, or in /etc/rc.conf
for boot time. Here are two examples for /etc/rc.conf for the
rl(4) and fxp(4) network drivers:
ifconfig_rl0="inet x.x.x.x netmask x.x.x.x media 100baseTX
mediaopt full-duplex"ifconfig_fxp0="inet x.x.x.x netmask x.x.x.x media 100BaseTX
mediaopt full-duplex"If you are fortunate enough to have one of the following network cards:
Note: If your card isn't listed here, do not give up hope! More drivers are being converted as demand comes in and you should look at the documentation for your driver to see if it is supported. If you're still unsure, join the freebsd-questions@freebsd.org mailing list from http://lists.freebsd.org/mailman/listinfo and ask there.
You can enable DEVICE_POLLING in your kernel. DEVICE_POLLING changes the method through which data gets from your network card to the kernel. Traditionally, each time the network card needs attention (for example when it receives a packet), it generates an interrupt request. The request causes a context switch and a call to an interrupt handler. A context switch is when the CPU and kernel have to switch from user land (the user's programs or daemons), and kernel land (dealing with device drivers, hardware, and other kernel-bound tasks). The last few years have seen significant improvements in the efficiency of context switching but it is still an extremely expensive operation. Furthermore, the amount of time the system can have to spend when dealing with an interrupt can be almost limitless. It is completely possible for an interrupt to never free the kernel, leaving your machine unresponsive. Those of us unfortunate enough to be on the wrong side of certain Denial of Service attacks will know about this.
The DEVICE_POLLING option changes this behavior. It causes the kernel to poll the network card itself at certain predefined times: at defined intervals, during idle loops, or on clock interrupts. This allows the kernel to decide when it is most efficient to poll a device for updates and for how long, and ultimately results in a significant increase in performance.
If you want to take advantage of DEVICE_POLLING, you need to compile two options in to your kernel:
options DEVICE_POLLINGoptions HZ=1000The first line enables DEVICE_POLLING and the second device slows the clock interrupts to 1000 times per second. The need to apply the second, because in the worst case your network card will be polled on clock ticks. If the clock ticks very fast, you would spend a lot of time polling devices which defeats the purpose here.
Finally we need to change one sysctl to actually enable this feature.
You can either enable polling at runtime or at boot. If you want to enable
it at boot, add this line to the end of your
/etc/sysctl.conf:
kern.polling.enable=1The DEVICE_POLLING option by default does not work with SMP enabled
kernels. When the author of the DEVICE_POLLING code initially commited it
he admits he was unsure of the benefits of the feature in a multiple-CPU
environment, as only one CPU would be doing the polling. Since that time
many administrators have found that there is a significant advantage to
DEVICE_POLLING even in SMP enabled kernels and that it works with no
problems at all. If you are compiling an SMP kernel with DEVICE_POLLING,
edit the file:
/usr/src/sys/kern/kern_poll.c and remove the following lines:
#ifdef SMP
#include "opt_lint.h"
#ifndef COMPILING_LINT
#error DEVICE_POLLING is not compatible with SMP
#endif
#endif
Mail servers typically have a very large number of network connections,
which transfer a small amount of data for a short period of time, before
closing the connection. Here is it useful for us to have a large number of
small network buffers.
Network buffer clusters are assigned two per
connection, one for sending and one for receiving. The size of the buffer
dictates how fast data will be able to funnel through the network, and in
the event of a network delay how much data will be able to backlog on the
server for that connection before there is a problem. Having a network
buffer too small means data will be backlogged at the CPU waiting for the
network to clear. This causes greater CPU overhead. Having a network
buffer too large means that memory is wasted as the buffer will not be
used efficiently. Finding this balance is key to tuning.
When we discuss simultaneous network connections, we refer to connections in any network state: SYN_SENT, SYN_RECV, ESTABLISHED, TIME_WAIT, CLOSING, FIN_WAIT, FIN_WAIT_2, etc. Even if the network connection is in an ESTABLISHED state for only a few seconds, it can end up in any of the other states for a long time. I generally find that multiplying the number of ESTABLISHED connections by 8 leaves me with room to breath in the event that I see an abnormally high surge of traffic inbound or outbound. I've come to this number over time through trial and error. So if you expect to have a peak of 128 servers sending you mail, having 2048 network buffer clusters would be good (128 * 2 per connection * 8). Also remember that connections can take up to two full minutes or more to close completely. So if you expect more than 128 mails in any given two minute period, you also need to increase the number to accomodate that.
Another important value to control is the maximum number of sockets. One socket is created per network connection, and one per unix domain socket connection. While remote servers and clients will connect to you on the network, more and more local applications are taking advantage of using unix domain sockets for inter-process communication. There is far less overhead as full TCP packets don't have to be constructed. The speed of unix domain socket communication is also much faster as data does not have to go over the network stack but can instead go almost directly to the application. The number of sockets you'll need depends on what applications will be running. I would recommend start with with same number of network buffers, and then tuning it as appropriate.
You can find out how many network buffer clusters in use with the
command netstat -m
You can specify the values you want, at the end of your
/boot/loader.conf file as:
kern.ipc.nmbclusters=2048kern.ipc.maxsockets=2048Note: With any performance tuning, it is important to monitor your system after you make your changes. Did you go overboard, or underestimate what you would need? Always check and adjust accordingly. The numbers here might not be the exact ones that you need!
Tuning the network for file servers is not unlike tuning mail servers. The main differences are:
Again we come back to network buffer clusters. How many clients do you have? With file servers the chances of a spike in the number of connections is small, as the number of clients is fixed. Therefore we do not need to set aside large numbers of buffers to accommodate spikes. Multiplying the number of network buffers by two is good practice, and some admins prefer to multiply by four to accommodate multiple file transfers.
So if we have 128 clients connecting to the file server, we would set
the number of network buffer clusters to 1024 (128 * 2 per connection * 4)
in /boot/loader.conf:
kern.ipc.nmbclusters=1024kern.ipc.maxsockets=1024Note: With any performance tuning, it is important to monitor your system after you make your changes. Did you go overboard, or underestimate what you would need? Always check and adjust accordingly. The numbers here might not be the exact ones that you need!
Web servers are not unlike mail servers. Unless you are doing a lot of file serving over the Internet, you will have clients connecting to you for short periods of time. If you have more than one element on your web page, for example multiple images or frames, you can expect that the web browsers of clients will make multiple connections to you. Up to four connections per page served are certainly not uncommon. Also if your web pages use server-side scripting to connect to databases or other servers, you need to add a network connection for each of those.
Web servers again like mail servers, go through periods of highs and
lows. While on average you might servers 100 pages a minute, at your low
you might server 10 pages a minute and at peak over 1000 pages a minute.
Whether you have 128Mb RAM, or 1Gb RAM, you should try and be as liberal
as possible in allocating memory to your network stack. Using the above
example, at a peak of 1000 pages per minute, your clusters and sockets
should be around 16384 (1000 pages * 2 per connection * 4 connections * 2
for growth) in /boot/loader.conf:
kern.ipc.nmbclusters=16384kern.ipc.maxsockets=16384Tuning your Apache or other web servers is slightly outside the scope of this paper, as there is already a ton of excellent data availible on the internet which I could never hope to do justice in this paper. A starting point I would recommend is Aleksey Tsalolikhin's notes from his Nov 2001 presentation to the Unix Users Association of Sothern California on web server performance tuning: http://www.bolthole.com/uuala/webtuning.txt, it should lead you on to more wonderful things.
Note: With any performance tuning, it is important to monitor your system after you make your changes. Did you go overboard, or underestimate what you would need? Always check and adjust accordingly. The numbers here might not be the exact ones that you need!
Optimizing the the disk subsystem on FreeBSD also depends on what you want to do with your system. It is very much installation dependent, so what I've done below is list the various factors and what they do. You can decide what is best for you.
WraithNet is a personally run network for free web hosting for anyone
publishing documents or data relating to the open-source community.
If you would like a sub-domain for your mail and web pages, send an email
to:
webmaster@silverwraith.com
This is a list of references I found when writing this paper. Most of them contain much more detail on their particular subject than I have provided here. Hopefully they will be as useful to you as they were to me.
If you find a problem with this website, please email:
webmaster@silverwraith.com
| Counter: 104334 page |